This handbook has been designed as a guide to the installation and operation of RTU5024 Gate Opener. Residential: Door,gate,garage access control, electronic fan,microwave,air-conditioner control. RTU5024 GSM Gate opener, GSM remote switch door opener SMS door control automatically open and close . For the first time to use RTU5024 GSM Controller, Fast start with following steps: GSM Garage Door Gate Opener Remote Relay Switch RTU5024. For example,you can use the output to ON or OFF a live wire of the motor power cable. Antenna: 50 SMA Antenna Interface7. The default password is 1234. This tutorial can be used as basics for such devices . Read item description or contact seller for postage options. Anwers 1: If no special description on the shopping page that is 3G or 4G version, you ordered GSM-RELAY products are 2G version.For some countries including: "USA, Australia, Singapore, Taiwan, Canada " must order the 3G or 4G version device. Business: Remote control electronic boxes,bright billboards,LED signs,etc, 850/900/1800/1900MHz or 3G WCDMA or 4G LTE, Relative humidity 90% (condensation free). There are no call costs, the GSM Gate Opener rejects the call from authorized number then carries out the turn ON/OFF action. Exterior dimension:110mm*90mm*40mm 5-15days for 1000pcs, if over 10,00pcs, please contact with us to confirm the accurate production time. 5) Questions About The size of the mounting box of the rain proof box : Any other questions on our products,please contact us: 1. This phone number is the only phone number that will receive a SMS reply in the event of relay state change due to call in action (Relay state change by call in the controllers SIM number) . Authorized phone number is a phone number that allowed to change the RTU5024 gate openers relay by call in action. Tel:+86-21-68458945 | Fax:+86-21-50454820 | Onservice Skype : 4G Design - will work anywhere in the world with 4G,3G and GSM Net, Secure caller ID allows controlled access of up to 100 authorized users, the users telephone numbers are added to the white list, only the numbers in the white list are able to activate the GSM-AUTO, users can be added and deleted as required using text messages, There are no call costs incurred when calling the unit, it will recognise an authorized telephone number calling it and reject the call without answering, The GSM-AUTO has two independent relays with normally open and normally closed contacts, these can be programmed to switch on for between 1 second and 18 hours, in addition a delay time between relay 1 and 2 switching can be set, programming is achieved by sending text messages to the GSM-AUTO, once programmed you simply call the unit to activate the relay operations already programmed, The programmed operation can be temporarily overridden and the relays switched on for up to 18 hours by sending the unit a text message command, a confirmation text will be returned when the relay(s) is switched on and another when it is switched off, The relays can be permanently switched on or off by sending the GSM-AUTO, a text message, again a confirmation text will be returned. Portugues Here is how to setup the master phone Number. There are no call costs, the GSM Gate Opener/Relay Switch rejects the call from authorized number then carries out the turn ON/OFF action. In addition, some other countries, GSM network no longer provide more future service and upgrades. Question 1: What is the difference between the RTU5024WAC and RTU5024WDC ? Newpass Password that you want to set as the New password. 7. Anwers:2-1: Do not place any useless letters before or after the instruction, or any extra spaces.Also must be sure,that command is right SMS command,Do not use instructions from other GSM devices on this device. Time Current password of the controller (00- 19) . GSM alarm system for home or industrial security alarm. GSM-AUTO 4G 3G GSM and CDMA Remote control switch (relay control switch) 586 have already sold. Applications: However , This depends on the settings you selected on the access control command section. 1. Since , Non of Australian mobile providers using 2G technology .This device will not works on such countries . So normally,we need to select at least DC12V/1A to DC12V 2A power supply for proper working with Relay ON. Anwers: 4: We can use your phone to dial the device number to control the relay output.There is a GOT timer ( For example 1234GOT005# ) you need to setup it before using. Copyright BLIIoT-BeiLai Technology Co., Ltd. Small Weather Station Monitoring Solution, Modbus, PLC to OPC UA by BL110 OPC Gateway, BL110 Connect Siemens S7-200Smart PLC to MQTT and OPC UA and BACnet/IP, S27X automatic planting monitoring system for soilless cultivation, D223 farm material tower weighing monitoring, Wireless IoT module is applied to the flat chicken house weighing scheme, S281 Data Acquisition System Andon Monitoring System, The Combination of MES with OPC UA IO Controller Enabling You to Optimize Your Entire Operation, Monitoring of Temperature, Pressure and Electric Energy of S275 Injection Molding Machine, Wireless IoT module remote computer room air conditioning monitoring, R40B 4G Edge Router Support Smart City Projects, RTU S275 Smart Light Pole Application Case, D223 tourist attraction gate data acquisition and monitoring, What features does IoT gateway need to have for smart city, RTU S272 Water Pump IoT Monitoring System, Liquid level converted to Flow by Industrial Edge Router for Parshall flume flow measurement, S130 remote control water pump on/off valve system, IoT Solution for Flow Meters with IoT100 and KPIIOT Cloud Platform, BMS110 24V 48V Battery Pack Remote Monitoring Solution, 4G Edge Industrial Router R10A for Photovoltaic System Monitoring, DTU photovoltaic power generation Internet of Things remote monitoring, Hospital Refrigerator Temperature Monitoring IoT Solutions, S265 + cord blood bank environmental monitoring, Blood Bank Refrigerator Temperature Monitoring, Forest fire warning remote wireless monitoring system, S175 paragliding club wind speed and direction detection, S272 elevator foundation pit environmental monitoring, S272 fire pump room environmental monitoring (water leakage, tank level, temperature and humidity), Sensor To Cloud intelligent parking lot location, gate monitoring, Wireless IoT module shares bicycle and car monitoring, S372 coal mine safety monitoring solution, Air Conditioner Remote Monitoring by M160E Dual network port Ethernet IO module, S281 wisdom fire hydrant water pressure monitoring, S475 negative pressure isolation chamber air pressure monitoring, S270 remote tower crane wind speed monitoring, Wireless IoT Gateway Helps Remote Monitoring Gas&Oil Pipelines Pressurization Station, Remote Online Monitoring System for Oilfield Pumping Units Based on Wireless IoT Gateway R40, Temperature and Pressure Monitoring of S475 Oil Pipeline, > 4G Solar Panel Battery Monitoring System, GSM 3G 4G Gate Opener 1 Relay, dial to open the gate, GSM 3G 4G Gate Opener 1 Relay, Dial to open/ switch on/off. Page 2 of 11 Ver 1.7 File No. 2. Anwers:1: Normally in our package,we have a paper manual inside the box, if you need to download it,then please go to : RTU5024 V2019 Manual de versin de caja a prueba de lluvia, Question 2: What is the new features of the V2019 version RTU5024? Anwers:1: For AC type,that power input is AC100-240V directly. you need to select other control board , For example our WF-TP02B controller, it has two relay output, two alarm input port and also have the temperature sensor input. RTU5024 GSM Gate Opener User Manual V1.7 | PDF - Scribd 0086-18675502646 (gates, bollards, barriers, garage doors, shutters and access doors or machines). The relay action will return a SMS confirmation to the owner or authorized call in number, this function is editable by user. Add or remove users by SMS Text command; 7. Then , slide it in the lock direction that mentioned in the sim holder. From 2016 was supported by Android and new version 2016 was supply by both IOS and android APP and more features supported better ! Step1: Go to Computer Windows Device manager to check if USB programmer has created a proper com port, if no COM port ,then check if you have already installed the USB driver.Normally after you pluged the USB programmer, Windows will find this new USB device and then you install the driver.If you are not sure how to install the USB device,then you can try to consult your friends with more more professional computer technology. Please put your sim card into it 2. Question 1: Where to download the V2019 RTU5024 Rainproof box type Manual ? For water pump,water tank,motor remote control,solar power remote monitor. The only thing missing is the input power to the unit . (gates, bollards, barriers, garage doors, shutters and access doors or machines); This will turn ON the relay for a set amount of time and turns OFF the relay .But ,You can type 00 as the Time if you wants the relay to be ON until it changed by SMS command or call in relay action. The GSM 3G 4G Gate Opener RTU5024 is an powerful wireless Relay, it is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipment, car parking systems. Identify the positive and the negative wires of the power supply (Use a multi meter if necessary ) and insert the positive wire to the positive terminal and negative wire to the negative terminal. Multiple applications. You need to match the frequency bands . No call charges. The GSM Gate Opener Remote Switch RTU5024 is a powerful GSM relay that can be used for authorized door access, controlling gates, switching of remote equipment, and car parking systems. SIM Card: Support 3V SIM Card6. This will reset the password and other settings of the controller to its original values. and you should connect the proper polarity to the power input port. The GSM Gate Opener/Relay Switch RTU5024 is an powerful GSM Relay, it is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipment, car parking systems. Controller instructions . Anwers:2-2: Pleae check your password ,if you have changed your password or other person changed the password, if cann't remember the passowrd, just RESET the device to orginal password "1234". " You can reset the controller to its factory settings by sending the Reset SMS command. 0086-18675502646document.write(unescape("%3Cspan id='cnzz_stat_icon_1280276768'%3E%3C/span%3E%3Cscript src='https://v1.cnzz.com/stat.php%3Fid%3D1280276768%26show%3Dpic1' type='text/javascript'%3E%3C/script%3E")); CopyRight 2021 All Right Reserved GATEOPENPOWERED BY YUKESitemapdocument.write(unescape("%3Cspan id='cnzz_stat_icon_1280276768'%3E%3C/span%3E%3Cscript src='https://v1.cnzz.com/stat.php%3Fid%3D1280276768%26show%3Dpic1' type='text/javascript'%3E%3C/script%3E")); Deutsch RTU5024 gate opener can be controlled both using SMS commands and mobile app . Questions About the working frequency: Q5: How about the Rutern this defective product? Phonenumber Phone number that you wants to add as the master phone number (Type with the country code +xx or 00xx format). and on the panel of the box,there is a "START" and "STOP" button. One output with relay rating 3A/240VAC for connecting the switch of the door or machines. There are two type of commands , One is setup commands and other is control commands. Then when you dial the GSM controller and it reject your calling,then you send an SMS automatically to the GSM controller,but for GSM controller,that is not an proper command,so it thinks that you use a wrong password and then reply you an SMS "Error password",so you need to disable this function of the SIM card in your mobile phone " Reject the calling with an SMS ". Question 1: Where to download the Rain proof type RTU5024 Manual ? Memorylocation Memory location that you wants to check the phone number at . . 6. But , If you selected all numbers access then any number that call your controller will cause relay state to change. Copyright 1999-2023 DIYTrade.com. Tighten the hex nut so that, The antenna firmly so that , there is no chance to loose the tightness. Question 1: What is the size of the RTU5024 box and the mounting hole dimension? If wrong,RTU5024 cann't be powered on. 1. One pcs GSM Magnet mount antenna (3 meter wire length) The GSM Gate Opener RTU5024 is a very smart designed device which can be used for authorized door access, controlling gates, car parking systems. Korean unauthorized user are not in your authorized numbers list,so they don't have the right to modify the parameters of your device and only can use the SMS command you give to them. Brief introduction The GSM Gate Opener RTU5024 is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipments, car parking systems. Secure - Using caller ID for identification,unknown callers are ignored; 001 being the memory location of the RTU5024 Gate Opener. . GSM Gate Opener, RTU5024 GSM Mobile Phone Access Controller Remote Control SMS $51.49 Last one Free shipping RTU5024 3G GSM Gate Opener Relay Remote Access Control Wireless Door Opener $69.50 Free shipping RTU5024 GSM Gate Opener Relay Remote Control Door Access Switch Free-Calling $16.86 +$7.99 shipping For some countries, for example,USA, Australia,Singapore and some Europe countries, they have already closed the service of GSM (2G) Net service,only provide the 3G or 4G net service.So for these countries, customer have to use the 4G controller. See details. Reply SMS You will get a SMS from the controller like this 001:Phonenumber . 10. Question 1: Where to download the RTU5024 Manual ? Please ,Checkout our RTU5024 mobile App tutorial . 3. Up to 200 authorized phone numbers can be configured at the specified time. Remote Control . The GSM 3G 4G Gate Opener RTU5024 is an powerful wireless Relay, it is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipment, car parking systems. Who will receive the confirmation SMS when the relay is ON/OFF. Francais Can be operated from anywhere, no distance limit. . Now you are ready to go . As we have mentioned early the antenna of the RTU5024 gate opener comes detached .So , You have to attach it . Additionally, it can also be used in places that require you to turn on/off your system, machines, or equipment remotely with a free call from your mobile phone. 1) Technical FAQ for Standard RTU5024 GSM Gate Opener: If you enable it with a SMS command you will get a SMS every time the relay change due to call in action. Portugues Turn the sim holder part down. The relay action will return a SMS confirmation to the owner, this function is editable by user; DC Power supply:DC12V/2A GSM Frequency: Quad-band 850/900/1800/1900MHz One output with relay rating 3A/240VAC for connecting the switch of the door or machines; The GSM-AUTO unit controls 2 independent switches. One output with relay rating 3A/240VAC for connecting the switch of the door or machines; 10. A3: The delivet time is based on the exact devices you confirmed. ( Must be noted: For 1000 users version, you need to setup the GOT data to 000, then will be switch mode ), Question 5: If I can connect a temperature sensor to the RTU5024 ? GSM Gate Opener, RTU5024 GSM Mobile Phone Access Controller Remote Control Switch SMS Door Control : Amazon.ca: Tools & Home . Memlocation Memory location to save the number (a number between 001 to 200 , If you selected a memory location that already occupied by a number that number will be replaced with the new number ) . 850/900/1800/1900MHz or 3G WCDMA or 4G LTE, Relative humidity 90% (condensation free). These above countries have to use 3G or 4G version,, because GSM net is already closed. The GSM Gate Opener Remote Switch RTU5024 is a powerful GSM relay that can be used for authorized door access, controlling gates, switching of remote equipment, and car parking systems. After you dial it, then relay output will be triggered for the GOT timer and then will back to previous status automatically. Production Time:Normally in stock model products: Quantity:1-100pcs only 2day ,Quantity:101-2000pcs need 3-15days, >2000pcs please contact with sales to confirm. But , different manufactures uses different set of commands . Opener/Relay Switch RTU5034 is an powerful GSM Relay, it is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipment, car parking systems. 7. Additionally, it can also be used in places which require you to turn on/off your system, machines, or equipment remotely with a free call from your mobile phone. Remote monitoring the Gate, Barrier, Shutter, Garage Door OPEN/Close Status! And later would need around 40mA current (Relay is at OFF Status). GSM Gate Opener Remote Relay Switch: User Manual But , If you disable it you wont get a SMS message. Secure Using caller-ID for identification, unknown callers are ignored. Because the unit doesnt answer the call, the activation of the relays does not incur any call charges to the PAYG plan or to the caller. RTU5024 GSM Gate Opener Relay Switch Remote Access Control - PiShop the GSM GPRS Relay Switch rejects the call from authorized number then carries out the turn ON/OFF action on the first ring. Gigital Output: NC/NO dry contact, 3A/240VAC or use this link to find the RTU5024 app link: https://itunes.apple.com/us/app/rtu5015/id1100111938?l=zh&ls=1&mt=8. SMS confirmation is the message you will get to the master phone number in the event of relay state change due to call in relay action. Humidity Range: Ralative Humidity 90%9. New Version(2023) RTU5024 4G GSM Gate Opener Relay Remote - eBay For DC type,that power input is AC/DC12-24V,don't need to distinguish which is positive and which is negative. A1: We are a manufactory, we supply the factory price with good quality, welcome to visit ! GSM Frequency: Quad-band 850/900/1800/1900MHz But , SMS commands will give you some options that not available with the mobile app . Anwers: 5: RTU5024 doesn't have any input port. That means it working very similar as your switch. Your email address will not be published. 1. There are few steps that need to be taken in order to use the RTU5024 gate opener . SHENZHEN,GUANGDONG,CHINA that means, that is a PULSE output. Learn more. RTU5024 is a professional GSM/3G/4G GATE OPENER, this is the product's operation manual. RTU5024 GSM Gate Opener Relay Switch Phone Wireless Remote Control Door Access. Although , Sending SMS commands are hard but it gives you full control of the features . New Version (2023) RTU5024 4G GSM Gate Opener Relay Remote Wireless Door Control. Website Article - https://learnitstepbystep.com/video/rtu5024-gate-opener-app-tutorial/RTU5024 SMS Commands Tutorial - https://learnitstepbystep.com/video/rt. Industry: Remote switch equipment, for example: street lights, solar power, motor, inverter, PLC, pumps, fans, etc. 1 x Good Gain Antenna. Additionally, it can also be used in places which require you to turn on/off your system, machines, or equipment remotely with a free call from your mobile phone. GSM Gate Opener Remote Relay Switch User Manual Ver 1.7 RTU5024 Date Issued: 2016-02-24 All rights reserved by King Pigeon Comm.Co.,Limited. Anwers:1: GSM net is working perfectly in most of the countries in the world. Moreover, the user can be authorized at the specified time to operate it, after timeout, will automatically change to unauthorized type. However , These settings doesnt involves changing any setting of the gate Opener. The controller comes in two different versions , One is for indoor use and the other version is for out door use . Question 2: How many outputs on one RTU5024 board ? Question 2: What is the usage for customized SMS command ? A5:First of all, please send us the pictures and videos of the product for confirmation. (2) Support maximum authorized 1000 numbers Based on GSM network, applied to many applications. We keep to upgrate our device more and more better. Arabic Lets discuss them . admin@gate-open.com PDF GSM Gate Opener GSM Remote Switch - ELKIM No need to provide a remote control or keys for different users; 8. SIM Card: Support 3V SIM Card 5. RTU5024 SMS Commands Tutorial - Learn it step by step 340 125K views 4 years ago GSM Gate Opener RTU5024 . and hash (#) which is used to separate each parameter of the command . Oldpassword Current password of the controller . Anwers:3: Normally in our package,we have a paper manual inside the box, if you need to download it,then please go to : Anwers:2: 2019 version RTU5024 has more features: Anwers:3: 2019 version Rain proof box version RTU5024 has added an external alarm input port, Anwers 4: For 2019 version, Power failure alert function is always enabled. Reply SMS You will get a SMS from the controller like this Memlocation:Phonenumber.
Forbo Marmoleum North Sea Coast, Articles G